Whitfield

Lifespan of Pellet Stove Igniters

Pellet Stove Igniters are a tricky group of products.  I say this because they are not all built the same and they can be unpredictable in how long they last with a few exceptions. The Pellet Stove Igniter used by Quadrafire pellet stoves fails the most frequently of any pellet stove igniter I know of.  […]

Posted in Austroflamm, Buyers Guide, Englander Pellet Stoves, Igniters, Quadrafire | Tagged , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , | Comments Off on Lifespan of Pellet Stove Igniters

Why is the Fan Blade Different?

Things keep getting changed and upgraded in the Pellet Stove World.  Motors and fan blades are one of the things that have been upgraded in the past few years. You may have noticed that the fan blade that came with your new motor looks different and may be smaller than what is on your old […]

Posted in Austroflamm, Buyers Guide, Englander Pellet Stoves, Exhaust/Combustion Fans, Quadrafire, Troubleshooting, Whitfield Pellet Stoves | Tagged , , , , , , , , , , , , , , , , , , | Comments Off on Why is the Fan Blade Different?

“Is This an Original Part or a Knock Off?”

Continuing my fight against High Home Heating Cost! I get this question every now and again from customers looking for parts for their stoves so I wrote this to refer you to for the answer because it’s not a simple “yes” or “no.” Stove manufacturers DO NOT make motors, electronics, wiring harnesses, control boxes or […]

Posted in Augers, Austroflamm, Buyers Guide, Convection Fans, Englander Pellet Stoves, Exhaust/Combustion Fans, Gas Stoves, Gas Stoves & Fireplaces, Igniters, Quadrafire, Troubleshooting, Whitfield Pellet Stoves | Tagged , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , | Comments Off on “Is This an Original Part or a Knock Off?”

“My Whitfield Pellet Stove Auger Motor Stopped”

A little more on Whitfield Pellet Stove auger motors that stop.  When an auger motor fails it usually just quits.  On a very rare occasion you might have one that just seems to get weak.  If so, replace it. DON’T WASTE YOUR TIME trying to repair an auger motor.  I have never heard of anyone […]

Posted in Whitfield Pellet Stoves | Tagged , , , , , , , , , , | Comments Off on “My Whitfield Pellet Stove Auger Motor Stopped”

How to replace a Whitfield Pellet Stove Auger Motor

Most pellet stoves are built exactly the same with few differences.  In my 10 years of repairing pellet stoves, I don’t remember every working on one with an auger motor that wasn’t installed this way.  I hope this helps. Unplug your stove from power. If your stove is free standing you will need to remove […]

Posted in Whitfield Pellet Stoves | Tagged , , , , , , , , | Comments Off on How to replace a Whitfield Pellet Stove Auger Motor

How To Find Glass For Your Whitfield Pellet Stove

It seems like once a week I get a call or email from a customer with an older Whitfield pellet stove that is looking for replacement glass.  This can be because the glass has cracked or the soot can actually bake into the glass and be nearly impossible to remove.  For whatever reason you need […]

Posted in Whitfield Pellet Stoves | Tagged , , , | Comments Off on How To Find Glass For Your Whitfield Pellet Stove

Amperage For Auger, Convection, Combustion/Exhaust Motors on Whitfield Pellet Stoves…What Should It Be?

I got a question today about the amperage listed on a motor that I sell for Whitfield Pellet Stoves.  The amperage on my new motor was different than the one he was replacing and he was concerned that it would not work correctly. Depending on when your Whitfield Pellet stove was made there may be […]

Posted in Whitfield Pellet Stoves | Tagged , , , , , , , , , , , , , , , | Comments Off on Amperage For Auger, Convection, Combustion/Exhaust Motors on Whitfield Pellet Stoves…What Should It Be?

How Do I Know If My Igniter Is bad?

    An ignitor element is very similar to a light bulb in that it turns on when you put power to it.  Ignitors get red hot when they are working, so a visual check is the first thing you want to do.  A working ignitor will glow red in under 2 minutes. If you […]

Posted in Igniters, Troubleshooting | Tagged , , , , , , , , , , , | Comments Off on How Do I Know If My Igniter Is bad?

Rebuilding or Resurrecting Whitfield Pellet Stove Motors

It seems like two or three times a week I get a call or email from a customer who is looking for information or parts to assist them with rebuilding a motor for their Whitfield pellet stove. This can be and auger motor, a convection fan or an exhaust/combustion blower. Usually there is a bearing […]

Posted in Whitfield Pellet Stoves | Tagged , , , , , , , , , , , , , , , , , , , , , | Comments Off on Rebuilding or Resurrecting Whitfield Pellet Stove Motors

Whitfield Pellet Stove Pellet Pile Ups, Low Heat, and Black Glass

I’ve had two phone calls and one email this morning about this same issue and I haven’t even made breakfast yet so I figure I should address it here.  This is the situation of having a very lazy flame that is smothered by incoming pellets usually accompanied by the glass getting black. The most common […]

Posted in Whitfield Pellet Stoves | Tagged , , , , , , , , , , , , , | Comments Off on Whitfield Pellet Stove Pellet Pile Ups, Low Heat, and Black Glass